Welcome to MEIKO.
Please select a country and click "confirm".
The clean solution

Automatic tray washing machine BTA 160, BTA 240

Wave water

This automatic tray washing machine features a powerful washing system located both above and below the tray to a maximum cleaning result. This is followed by an intensive hot fresh water final rinse of each tray. To ensure a first class drying result the tray transport cords of the BTA tray washer are separated between the final rinse section and the drying zone. Trays are therefore transported on „dry“ round belt cords when in the drying zone for a optimal drying performance.

Measurements

Standard
Technical data
Drying/air circulation200 m³/h
Performance
Wash capacity16 trays/min
Pump motor1,1 kW
Tank capacity 60 l
Final rinse 150 l/h
Blower motor4 kW
Built-in boiler
40°C feed water temperature13,9 kW
10°C feed water temperature17,6 kW
Total connected load
10°C feed water temperature without heat recovery system39 kW
10°C feed water temperature with heat recovery system33 kW
40°C feed water temperature29 kW

The compact construction and the exceptional price/performance ratio make the BTA 240 automatic tray washer a must have! Trays no longer need to be picked-up and placed on the washing machine belt manually, keeping costs lower with shorter washing-up times, reduced working hours and less energy consumption.

The optional heat recovery condensing system uses the otherwise extracted steam vapours for the pre-heating of the incoming cold water supply, whilst considerably reducing the humidity and temperature of the remaining exhausted air. (Also available for the BTA 160.)

Punkt2 AirConcept M-iQ
Heat recovery to enhance air qualitiy and energy efficiency

Heat recovery to enhance air qualitiy and energy efficiency

Measurements

Standard
Technical data
Drying/air circulation2 x 200 m³/h
Performance
Wash capacity24 trays/min
Pump motor1,1 kW
Tank capacity 60 l
Final rinse 225 l/h
Blower motor2 x 4 kW
Built-in boiler
40°C feed water temperature13,9 kW
10°C feed water temperature17,6 kW
Total connected load
10°C feed water temperature without heat recovery system47 kW
10°C feed water temperature with heat recovery system40 kW
40°C feed water temperature36 kW

Product lines and configurations may vary from one country to the next due to statutory requirements or other reasons. Please check with your local trade partner. They will be happy to find a machine that meets your specific requirements.
Date: 06.2018. Technical modifications reserved.